Thiết bị đo áp suất Pascal CI4100
Thiết bị đo áp suất Pascal CI4100 Labom tại Việt Nam
PRESSURE TRANSMITTER PASCAL CI4100
Labom Việt Nam
Features
  • Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids
  • Stainless steel case in sturdy design, degree of protec-tion IP 65/67
  • Accuracy 0.1 %
  • High-resolution graphic display with Intuitive 4-button operation and backlight
  • Comprehensive parameterising functions
Options
  • Explosion protection for gases and dust
  • Classification per SIL2
  • Certificate of measuring equipment for Russian Federation
  • Material certificate per EN 10204
  • Calibration certificate per EN 10204
TECHNICAL DATA
Measuring ranges
Measuring ranges :
see data sheet
Constructional design / case
Design:
Two-chamber case, continuously rotatable by ± 170°
Case surface blasted
Material case:
- Stainless steel mat.no. 1.4301/1.4305 (304/303)
- Stainless steel mat.no. 1.4404 (316L)
Material front cover:
- Polypropylene, black
- Stainless steel mat.no. 1.4305 (303)
- Stainless steel mat.no. 1.4404 (316L)
Gaskets:
Silikone / NBR
Degree of protection per EN 60529:
- IP 65 / IP 67
- IP 69K
Climatic cate-gory per EN 60721 3-4:
4K4H
Vibration resistance per EN 61298-3:
10…60 Hz: ± 0,35 mm
60…1000 Hz: 5 g
Material window:
- Macrolon
- Non splintering glass (requires front cover of stainless steel)
Elec. connec-tion:
- Circular connector M12 
- Cable gland M16x1.5, PA black 
- Cable gland M16x1.5, stainless steel 
- Cable gland M20x1.5, PA black
- Cable gland M20x1.5, stainless steel 
- 1/2" NPT, PA black
Further connections upon request
Terminal blocks:
- Spring clamp terminals up to 1.5 mm2
- Pole terminals up to 2.5 mm2
- Screwed terminals up to 2.5 mm2
Weight:
Approx. 1.4 kg
Type plate:
Laser marking
Process connection
Position:
- bottom 
- back
(Flush mounting upon request )
Design:
- G1/2 B per EN 837-1
- G1/4 B per EN 837-1
- G1/4 A per DIN 3852 Form E
- 1/2" NPT
- 1/4" NPT
Further process connections upon request
Material messstoffberührte Teile
Sensor:
piezoressistive
thin film
Sensor diaphragm:
1.4404/1.4435 (316L)
1.4542 (630)
Socket:
1.4404/1.4435 (316L)
1.4301/1.4404 (304/316L)
Measuring system
Sensor:
piezoresistive
thin film
Sensor filling:
Synthetic oil, free of silicone FD1, FDA listed
without
Accuracy
Reference cond.:
per EN 60770-1
TU = const. (15…25) C
φ = const. (45...75) % r.F.
pU = const. (860...1060) mbar
UB = 24 V DC (± 3 V DC)
RB = 50 Ω, HART: 250 Ω
Ground connected 
MBA = 0 bar
Calibration position:
Process connection bottom: vertical
Process connection back: horizontal
Deviation of characteristic:
Refer to the adjusted measuring span (Limit point method per DIN 16086)
Nominal range 1-400 bar, 1-16 bar abs.
Turndown 5:1; 0.1 %
Turndown > 5:1; 0.02 % x TD
Nominal range 0.25 bar
Turndown 5:1; 0.15 %
Turndown > 5:1; 0.03 % x TD
Long-term drift:
Refer to nominal range ≤ 0,1 %/Jahr
Operational availability:
< 12 s
Response time t90 at current output:
for 20 Hz measuring rate: typically 120 ms
for 100 Hz measuring rate: typically 50 ms
Temperature influence, case:
Refer to nominal range
Ambient temperature -20…80 °C:
Nominal range 1-400 bar 0.1 %/10K , max. 0.3 %
Nominal range 1-16 bar 0.1 %/10K , max. 0.3 %
Nominal range 0.25 bar 0.15 %/10K, max. 0.4 %
Ambient temperature -40…-20 °C:
Typical 0.2 %/10K
Indication
Display:
- High-resolution graphic display with backlight
- 4-button operation
- Freely configurable display modes
- continuously rotatable by ± 170 (de-tent every 90°)
- Optional: Remote display and control unit, can be used up to 10 m away from measuring point
Configuration memory:
- All parameterisation data can be cop-ied from the device into the configuration memory in the display module. The data is permanently stored there, even in the event of power failure.
- The parameters can be transferred simply and quickly to other devices.
Output
Signal:
2-wire technology 4…20 mA
Lower limit 3.8…4 mA
Upper limit 20…21 mA
Lower alarm current < 3.6 mA
Upper alarm current > 21 mA
Current limitation 22 mA
Digital communication: HART ® protocol, version 7
Communication via: 
- Siemens PDM
- Pactware or compatible systems (FDT/DTM)
- 375 / 475 Field Communicator
Function:
Adjustable:
- Linear
- Inverse response
- By square root
- Table function with up to 64 support points
Turndown:
Max. 100:1
Damping:
0…999.9 s selectable in steps of 0.1 s
Measuring rate:
20 Hz, switchable to 100 Hz
Resolution:
1 µA
Current sensing func.
3.55…21.5 mA selectable in steps of 0.001 mA
Load RB:
RB ≤ (UV-12V DC)/0,022 A [Ohm]
UV = supply voltage
for HART communication: RB ≥ 230 Ω
Supply voltage
Functional range:
12…30 V DC, protected against polarity reversal
Ripple:
< 5 %
Temperature ranges
Ambient:
-40…80 °C (Display visibility is limited at temperatures below - 30 °C)
Media:
-40…100 °C
Storage:
-40…80 °C
Tests and certificates
See documents
Type series
CI4100, CI4103
Xem thêm các sản phẩm khác của Hãng tại đây

Thiết bị đo áp suất Pascal CI4100 - Labom Việt Nam

Bình luận của bạn
*
*
 Captcha
Danh sách Sản phẩm
Hỗ trợ trực tuyến
Liên hệ tư vấn mua hàng
Thống kê truy cập
  • Trực tuyến:
    3
  • Hôm nay:
    583
  • Tuần này:
    3459
  • Tháng trước:
    17426
  • Tất cả:
    2007900
Video ClipVideo Clip
CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

Công ty TNHH Thương mại và Dịch vụ Tăng Minh Phát

  1. VPĐD: Số 1, Đường số 27, Phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM

  2. Nhân viên kinh doanh: Trung ( Mr.Trung)

  3. Email:  sale18@tmpvietnam.com        Tel:  0914.981.967

  4. VP tại Đức: Am Boscheler Berg 4a 52134 Herzogenrath

  5. Website: gianhangtudonghoa.com

Chính Sách Mua Hàng

 

   Giao hàng miễn phí.

   Làm việc các ngày trong tuần.

   Thanh toán linh động.

    Bảo hành 12 tháng.

Bản đồ

 

Công ty Tăng Minh Phát

 

© 2017 Tangminhphat.com, all right reserved.

Thiết kế website www.webso.vn

Loading...

Back To Top